ESC S
Function:
Select standard mode
Code:
ASCII
ESC
S
Hex
1B
53
Decimal
27
83
Range:
None
Default:
None
Description:
This command enables standard mode.
Remarks:
The data in the printer buffer is cleared and the setting by ESC W returns to the default.
The conditions by the following commands are defined independently in standard mode and page mode.
ESC SP, ESC 2, ESC 3, ESC U, and FS S
In standard mode, CAN, GS $, and GS \ are ignored.
Differences:
None