BIXOLON SRP-352plusIII Manuale Utente Pagina 43

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 120
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 42
SRP-350/352plusIII
Rev. 1.00 BIXOLON
- 43 -
ESC a
Function:
Set position alignment
Code:
ASCII
ESC
a
n
Hex
1B
61
n
Decimal
27
97
n
Range:
0 ≤ n ≤2, 48 ≤ n ≤50
Default:
n = 0
Description:
This command specifies position alignment for all data in one line in standard mode, using n as follows:
n
Alignment
0, 48
Left alignment
1, 49
Center alignment
2, 50
Right alignment
Remarks:
This command is not effective in page mode. If this command is processed in page mode, the setting by this
command becomes effective when the printer returns to standard mode.
The setting of this command remains effective until ESC !, ESC @, printer reset or power cycling is executed.
Differences:
None
Vedere la pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 119 120