<Function 167> GS ( k pL pH cn fn n (fn=67)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
31
43
n
Decimal
29
40
107
3
0
49
67
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=67
1<=n<8
Default:
n = 3
Description:
This command sets the size of the QR Code module to n dots.
Remarks:
The setting of this command affects the processing of <Function 181>.
Since the QR CODE module is square, n = module width = module height.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None